Turbo Air Reach-In Refrigerators & Freezers - PRO-26-2F-N(-L) PRO

PRO Series Freezer, reach-in, one-section, 24.39 cu. ft., 28-3/4"W x 34-1/8"D x 78"H, top mount self-contained refrigeration, self-cleaning condenser device, digital temperature controller, self-diagnostic monitoring system, hot gas condensate system, automatic fan motor delays, (2) solid half doors with locks, lifetime guaranteed heavy duty hinges & handles, LED interior lighting, (3) stainless steel wire shelves, stainless steel interior & exterior (galvanized top & bottom), R290 Hydrocarbon refrigerant, 1/2 HP, 115v/60/1-ph, 7.0 amps, NEMA 5-15P -Sanitation, Made in USA (contact sales for lead time)

What Our Experts Think
  • Space-Saving & High-Capacity: The Turbo Air PRO Series Reach-In Freezer offers a spacious 24.39 cu. ft. of storage in a compact, one-section design (28-3/4"W x 34-1/8"D x 78"H). It's an ideal solution for kitchens needing efficient frozen storage in a smaller footprint.

  • Advanced Cooling Performance: Equipped with top-mount self-contained refrigeration, this freezer delivers reliable and consistent cooling. The self-cleaning condenser device minimizes maintenance needs, helping the freezer operate efficiently and prolong its lifespan.

  • Precise & Convenient Controls: The digital temperature controller and self-diagnostic monitoring system ensure accurate temperature management and ease of use, while real-time diagnostics streamline troubleshooting.

  • Energy Efficient: With features like a hot gas condensate system, this freezer optimizes energy use, reducing power consumption and lowering operating costsโ€”perfect for businesses looking to minimize their energy footprint.

  • Durability & Ease of Maintenance: The stainless steel construction of the interior and exterior ensures the freezer is both durable and easy to clean, maintaining hygienic standards and offering long-lasting performance.

Q&A

Q: What are the key features of the Turbo Air PRO-26-2F-N(-L) PRO Series Freezer?
A: The Turbo Air PRO-26-2F-N(-L) PRO Series Freezer is a one-section reach-in freezer with a 24.39 cu. ft. capacity. It features top-mount self-contained refrigeration, a self-cleaning condenser device, a digital temperature controller, a self-diagnostic monitoring system, and a hot gas condensate system for efficient cooling and maintenance.

Q: What are the dimensions of the Turbo Air PRO-26-2F-N(-L) PRO Series Freezer?
A: The freezer measures 28-3/4" in width, 34-1/8" in depth, and 78" in height.

Q: What is the storage capacity of the Turbo Air PRO-26-2F-N(-L) PRO Series Freezer?
A: The freezer has a 24.39 cu. ft. storage capacity, suitable for medium to large frozen food storage needs.

Q: What type of refrigeration system does the Turbo Air PRO-26-2F-N(-L) PRO Series Freezer use?
A: The freezer uses top-mount self-contained refrigeration for effective cooling and ease of maintenance.

Q: Does the Turbo Air PRO-26-2F-N(-L) PRO Series Freezer have a self-cleaning condenser?
A: Yes, the freezer features a self-cleaning condenser device to help maintain optimal performance and reduce service frequency.

Q: What temperature control features does the Turbo Air PRO-26-2F-N(-L) Freezer have?
A: It includes a digital temperature controller and a self-diagnostic monitoring system, ensuring precise temperature management and easy troubleshooting.

Q: What additional features are included in the Turbo Air PRO-26-2F-N(-L) Freezer?
A: The freezer includes a hot gas condensate system to prevent water buildup and automatic fan motor delays for energy efficiency and consistent performance.

Maintenance Tips
  • Routine Cleaning: Clean the exterior and interior of the freezer regularly to maintain a clean environment. Use a mild detergent and non-abrasive cloth for the stainless steel surfaces. For the interior, wipe down shelves and surfaces to avoid the buildup of food debris and moisture.

  • Condenser Maintenance: While the freezer is equipped with a self-cleaning condenser device, it's important to regularly check the condenser for debris buildup, especially in environments with high dust or grease levels. Clear any obstructions to ensure optimal performance.

  • Temperature Check: Regularly monitor the digital temperature controller to ensure the freezer is functioning within the recommended temperature range. If the temperature is inconsistent, check the settings and recalibrate if needed.

  • Inspect Door Seals: Check the door seals for cracks, wear, or damage. Properly functioning seals are essential to maintain the unitโ€™s efficiency by preventing cold air from escaping. Clean the seals with warm, soapy water and replace them if damaged.

  • Hot Gas Condensate System: Inspect the hot gas condensate system to ensure proper drainage. Make sure the drain lines are clear to avoid water buildup, which can cause damage and reduce the unitโ€™s cooling efficiency.

  • Defrosting Cycle: Although the freezer has an automatic defrost cycle, itโ€™s a good idea to monitor the defrost process periodically. If ice buildup occurs, manually defrost the unit to avoid overworking the refrigeration system.

  • Ensure Proper Airflow: Ensure that the shelves are adjusted correctly and that thereโ€™s enough space around the unit for adequate airflow. This ensures the unit operates efficiently and keeps the temperature stable inside.

  • Self-Diagnostic Monitoring: Take advantage of the freezerโ€™s self-diagnostic monitoring system. Regularly check for any error codes or performance issues. This will help detect potential problems early, minimizing downtime and costly repairs.

  • Fan Motor Delays: Check that the automatic fan motor delays are working as intended. This feature helps reduce unnecessary cycles and prolongs the lifespan of the compressor and fan.

  • Check Electrical Components: Regularly inspect the electrical components, including the wiring and plugs, for any signs of wear or damage. If you notice anything unusual, have a technician inspect the system.